Ceiling Panels - Clean Room | USG Boral ME

Designed for clean-room environment, these acoustic panels are adhere to ISO Cleanroom Standard and sag-resistant.

CLEAN ROOM Acoustic Panel have an embossed, vinyl-laminated face with sealed back and edges for use in Class 100 (cross reference to Class 5 per ISO 14644-1) or 10M-100M clean rooms as per Federal standard 209E for Classification by Airborne particles.

These are made with Fire code base materials to meet life safety codes. They are available in un-perforated finish for Kitchen & food preparation areas and perforated to meet acoustical requirements in hospitals. Clean Room is  Classified HRC panels (High Recycled Content) which is greater than 50%.

Required to be used with CE grid (gasketed tee flanges) for Operating theaters & MRI rooms.

Features & Benefits:

  • - Certified USDA/FSIS bio-based product requirements for food processing areas where Clean Room has achieved both Bio-Preferred initiatives: Federal Procurement Preference and Certified Product Labeling
  • - Cleanroom classified, meets Federal Spec. 209E for non-perforated “Clean Room and work station Requirements, controlled environment”
  • - Washable, scrubbable resistance
  • - High humidity resistant and anti-mold, mildew growth
Physical Properties:
  • Provide Acoustical Ceiling Material manufactured to meet requirements of this specification in accordance with ASTM E 1264 and EN 13964
  • Type X, Pattern [C] [G] [I]
  • Embossed Vinyl-faced with field cut-edges sealed with white latex paint
  • Size 15mm thick [600 x 600] [600 x 1200]
  • Edge Detail Trim (Square)
  • Noise Reduction Coefficient (NRC) [0.15] [0.55]
  • Ceiling Attenuation Class (CAC) [35-37 dB]
  • Light Reflectance Coefficient (LR) 0.80
  • Recycled Content [52%]
  • Color White similar to RAL 9016
  • Surface Burning Characteristics per ASTM E 84 Class A, Flame Spread: 10, Smoke development: 20 Reaction to Fire: Euroclass A2-s1,d0 in accordance with EN-13501-1
  • Underwriters Laboratories Inc. Fire-Resistance (ASTM E 119) ANSI/UL 263 Time-Rated Assembly [3hrs] [D218]
  • Thermal Resistance: 0.23 m² °K/W - R 1.3
  • Humidity Resistance Maximum 99% RH / 40°C for ClimaPlus
  • Weight: 5.25kg/m²
  • Mold Prevention: Inherent to Mold/Mildew growth
  • Relevant LEED Credit: EA Credit 1 | MR Credit 4| MR Credit 5 | MR Credit 6 | ;IEQ Credit 3 | ; ;IEQ Credit 3.2 | IEQ Credit 4.6 | IEQ Credit 8.1 | IEQ Credit 9
  • Thickness Tolerance ± 1.5 mm as per EN 13964.
    Applications:
  • Sterile rooms
  • Laboratories
  • Food/ beverage processing (non-perforated only)
  • Emergency rooms
  • Toilet/Wet rooms
  • Operating/MRI rooms
  • Installing Your USG Ceiling Grid and Tile