SS21 FIRE RATING 2,5 HOURS - ACOUSTIC

SS21 Fire Rating 2,5 Hours - Acoustic

Introduction

This partition system developed to meet the requirements of Fire Resistant up to  2,5 hours (FRL -150/150) with sound absorption performance.

Suitable to applied at:

  • Exhibition Hall
  • Karaoke room partition
  • Library
  • Meeting room and any other area that require optimum fire rating and acoustical performances.

Supporting Material:

  • Frame: JayaBMS Wall Track, JayaBMS C Stud, JayaBMS Deflection Head Track, JayaBMS Direct fixed clip + JayaBMS Furring Channel (Thickness min. 0,5mm BMT)
  • Lining: 2 layer of Firestop 16mm (2 sides) + 1 layer of  Jayabell 12mm (1 side)
  • Jointing: JayaCompound as Jayaboard recommendation.

Use Hitung Material fiture to help you figure total materials needed.

Specification:

  • Fire Rating: Up to FRL -/150/150
  • Acoustic Rating: STC 51 (no insulation), STC 59 (insulation 60kg/m3)
  • Weight: 63 Kg/m2
  • Grade (BS 5234): Severe Duty

Notes:

  • All the materials above calculated based on a room with a size of (3 x 33.33m).  Another room sizes should be considered further.
  • Stud frame gap max. of 600mm.
  • All the materials above needs to be reconfirmed by the Contractor/ Applicators regarding bookings material inquiry order.
  • Exclude waste material.

Information provided are for reference purpose only and due care has been taken to ensure accuracy at time of publication. Products, specifications and requirements may vary according to geographical locations and applications. As each project is unique, please contact your local Jayaboard representative for further assessment.